Windows

Previous
Next

Innovative functional solutions, safety and energy saving

PVC windows have a number of features that recommend them as the optimal solution for all types of homes. Easy maintenance, low costs, thermal and acoustic performance are essential factors for anyone in choosing carpentry.

00436C

System geometry

82 mm
3 seals
7 isolation rooms

Thermal performance

UF ≥ 1,0 W / m2K
UW ≥ 0,67 W / m2K

00436C

Maximum glazing thickness

48 mm

00436C

Acoustic performance

48 dB

00436C

Profile class

A

00436C

System geometry

82 mm
2 seals
7 isolation rooms

Thermal performance

UF ≥ 1,00 W / m2K
UW ≥ 0,67 W / m2K

00436C

Maximum glazing thickness

48 mm

00436C

Acoustic performance

48 dB

00436C

Profile class

A

00436C

System geometry

82 mm
3 seals
6 insulation rooms in frame and sash

Thermal performance

UF ≥ 1,00 W / m2K
UW ≥ 0,67 W / m2K

00436C

Maximum glazing thickness

60 mm

00436C

Acoustic performance

48 dB

00436C

Profile class

A

00436C

System geometry

116 mm
2 seals
7 isolation chambers in the frame and 6 in the sash

Thermal performance

UW ≥ 0,70 W / m2K

00436C

Maximum glazing thickness

52 mm

00436C

Acoustic performance

48 dB

00436C

Profile class

A

00436C

System geometry

82 mm
renovation frame: 30 and 65 mm
3 seals
7 isolation chambers in the frame and 6 in the sash

Thermal performance

UF ≥ 1,00 W / m2K
UW ≥ 0,67 W / m2K

00436C

Maximum glazing thickness

60 mm

00436C

Acoustic performance

48 dB

00436C

Profile class

A

00436C

System geometry

70 mm
2 seals
5 insulation rooms in frame and sash

Thermal performance

UF ≥ 1.30W / m2K,
UW ≥ 1.00W / m2K

00436C

Maximum glazing thickness

36 mm

00436C

Acoustic performance

48 dB

00436C

Profile class

A

00436C

System geometry

70 mm
renovation frame: 30/35 / 39,5 / 65 mm
2 seals
5 isolation rooms

Thermal performance

UF ≥ 1,30 W /2K
UW ≥ 1,00 W / m2K

00436C

Maximum glazing thickness

36 mm

00436C

Acoustic performance

48 dB

00436C

Profile class

A

00436C

System geometry

70 mm
insulation frame: 106/126/146/166 mm
2 seals
5 isolation rooms

Thermal performance

UF ≥ 1.30W / m2K,
UW ≥ 1.00W /2K

00436C

Maximum glazing thickness

36 mm

00436C

Acoustic performance

48 dB

00436C

Profile class

A

00436C

System geometry

76 mm
3 seals
6 insulation rooms in frame and sash

Thermal performance

UF ≥ 1,00 W / m2K
UW ≥ 0,80 W /2K

00436C

Maximum glazing thickness

48 mm

00436C

Acoustic performance

48 dB

00436C

Profile class

B

00436C

System geometry

70 mm
2 seals
5 insulation rooms in frame and sash

Thermal performance

UF ≥ 1.30W / m2K,
UW ≥ 1.00W / m2K

00436C

Maximum glazing thickness

36 mm

00436C

Acoustic performance

48 dB

00436C

Profile class

B

00436C

System geometry

70 mm
2 seals
5 insulation rooms in frame and sash

Thermal performance

UF ≥ 1.30W / m2K,
UW ≥ 1.00W / m2K

00436C

Maximum glazing thickness

36 mm

00436C

Acoustic performance

48 dB

00436C

Profile class

B

00436C

System geometry

82 mm
3 seals
7 isolation rooms

Thermal performance

UF ≥ 1,0 W / m2K
UW ≥ 0,67 W / m2K

00436C

Maximum glazing thickness

48 mm

00436C

Acoustic performance

48 dB

00436C

Profile class

A

00436C

System geometry

82 mm
2 seals
7 isolation rooms

Thermal performance

UF ≥ 1,00 W / m2K
UW ≥ 0,67 W / m2K

00436C

Maximum glazing thickness

48 mm

00436C

Acoustic performance

48 dB

00436C

Profile class

A

00436C

System geometry

82 mm
3 seals
6 insulation rooms in frame and sash

Thermal performance

UF ≥ 1,00 W / m2K
UW ≥ 0,67 W / m2K

00436C

Maximum glazing thickness

60 mm

00436C

Acoustic performance

48 dB

00436C

Profile class

A

00436C

System geometry

116 mm
2 seals
7 isolation chambers in the frame and 6 in the sash

Thermal performance

UW ≥ 0,70 W / m2K

00436C

Maximum glazing thickness

52 mm

00436C

Acoustic performance

48 dB

00436C

Profile class

A

00436C

System geometry

82 mm
renovation frame: 30 and 65 mm
3 seals
7 isolation chambers in the frame and 6 in the sash

Thermal performance

UF ≥ 1,00 W / m2K
UW ≥ 0,67 W / m2K

00436C

Maximum glazing thickness

60 mm

00436C

Acoustic performance

48 dB

00436C

Profile class

A

00436C

System geometry

70 mm
2 seals
5 insulation rooms in frame and sash

Thermal performance

UF ≥ 1.30W / m2K,
UW ≥ 1.00W / m2K

00436C

Maximum glazing thickness

36 mm

00436C

Acoustic performance

48 dB

00436C

Profile class

A

00436C

System geometry

70 mm
renovation frame: 30/35 / 39,5 / 65 mm
2 seals
5 isolation rooms

Thermal performance

UF ≥ 1,30 W /2K
UW ≥ 1,00 W / m2K

00436C

Maximum glazing thickness

36 mm

00436C

Acoustic performance

48 dB

00436C

Profile class

A

00436C

System geometry

70 mm
insulation frame: 106/126/146/166 mm
2 seals
5 isolation rooms

Thermal performance

UF ≥ 1.30W / m2K,
UW ≥ 1.00W /2K

00436C